Direct Application Vent Panel

Direct Application Vent Panel (image 1 of 1)
Click on large image to see full sized

Direct Application Vent Panel

Flannery's Direct Application Vent Panels are an excellent tool for ventilating soffits or attic spaces. Our Direct Application Vent Panel can be utilized in both new construction and retrofits. They are a perfect solution for replacing rusted out or damaged vents since they can easily be inserted into the existing vent opening. We call these vents "Direct Application" because their nailing flanges have a beveled edge to them in order to allow the installer to apply the final finish. 

Vent Panels are ideal for drawing cooler air into the attic forcing warm or stale air to be exhausted through ridge, gable, and turbine vents. Many "do-it-yourself" stores sell aluminum vents that are as thin as a soda can which can easily be chewed through or damaged. All of Flannery's Vent Panels have a .050" thick walls, which make them some of the sturdiest vent panels on the market. Since our Vent Panels contain vent slots (1" x 1/8") and not holes, bees, wasps, and many other insects cannot fly or crawl through the vent. 

While many screen vents and other steel vents will eventually rust out, Flannery's Vent Panels will never rust out since they are manufactured from extruded aluminum. Flannery manufactures various sizes and lengths of the Direct Application Vent Panel. We also will make customs lengths if needed (10 Vent Panel minimum).

Manufacturer's Specification

Direct Application Vent Panels are standard extruded aluminum alloy 6063 T5 and are .050" thick. Direct Application Vent Panels shall have a standard Mill Finish. To prevent oxidation spots, mill finished products must be covered with a primer and paint. Be sure to prevent primer and paint from clogging the vent slots. Clear Anodized and Alodine (Chemfilm) finishes as well as other factory finishes and custom paint orders are available. Refer to Finishes for details.

Install all Direct Application Vent Panels to the framing with nails, screws, or other approved fastening methods. Direct Application Vent Panels should be inserted into the pre-cut ventilation area and attached to the joists. They can be attached through their nailing flanges on both sides. Direct Application Vent Panels can be utilized with E.I.F.S. (Drivit, STO, Parex, etc.) finishes. They also work with DensGlass Gold panel systems and USG's Exterior Gypsum Ceiling Board among other types of approved exterior sheething.

For Material Safety Data Sheet (MSDS Report), click here.

 

 

 

 

Part No.

"A" Reveal Width

"B"  Flange  Width

"C" Depth

   DWR 50-VP-50    1/2" 2.25" 1/2"
DWR 50-VP-75 3/4" 2.50" 1/2"
 DWR 50-VP-100 1" 2.75" 1/2"
  DWR 50-VP-150  1 1/2" 3.25" 1/2"
 DWR 50-VP-200 2" 3.75" 1/2"
 DWR 50-VP-300 3" 4.75"  1/2"
 DWR 50-VP-600 6" 7.75"  1/2"
 DWR 625-VP-50 1/2" 2.25" 5/8"
   DWR 625-VP-625  5/8" 2.375" 5/8"
 DWR 625-VP-75 3/4" 2.50" 5/8"
  DWR 625-VP-100 1" 2.75"  5/8"
  DWR 625-VP-150 1 1/2" 3.25" 5/8"
  DWR 625-VP-200 2" 3.75" 5/8"
  DWR 625-VP-300 3" 4.75" 5/8"
  DWR 625-VP-400 4" 5.75" 5/8"

 

 

 

 

 

Vent Area Graph

Reveal Width

Vent Slots Vent Area Per Lineal Foot Approx
1/2" 1 1 sq. inch
3/4" 1 1 sq. inch
7/8" 1 1 sq. inch
1" 1 1 sq. inch
1 1/2" 2 2 sq. inch
2" 3 3 sq. inch
2 1/2" 3 3 sq. inch
3" 5 5 sq. inch
4" 7 7 sq. inch
6" 8 8 sq. inch

 

 Installation Detail- Side View 

 

Installation Detail- Angled View with Finish

 

Installation Detail- Frontal View with Finish

 

 

 

 

 

 

 

This website presents general guidelines and suggestions for the installation of Flannery trims and products. The purpose of these general guidelines and suggestions is to aid in a successful drywall or stucco finish based on the Uniform Building Code and industry standards. No website or catalog can address all of the unique specifics or installation details that occur from one project to another. Flannery recommends that every installer be familiar, or become acquainted with, common drywall and stucco trim installation practices before installing any of Flannery's many trims and products. Flannery also recommends that the specifying architect, engineer, and general contractor be consulted with as well. This website replaces and renders obsolete all previous publications by Flannery; including catalogs, pamphlets, or other forms of literature. 




 
 